up-dwn-cntr = 0
self-test = passed
noise-margin-down = 0
attenuation-down = 0
output-power-down = 0
noise-margin-up = 0
attenuation-up = 0
output-power-up = 0
near-end-fec = 0
near-end-crc = 0
near-end-hec = 0
far-end-fec = 0
far-end-crc = 0
far-end-hec = 0
received-rs-blcks = 0
transmitted-rs-blocks = 0
incoming-cells = 0
outgoing-cells = 0
Parameter
line-up-timer
rx-signal-present
up-down-cntr
self-test
noise-margin-down
attenuation-down
output-power-down
noise-margin-up
attenuation-up
output-power-up
near-end-fec
near-end-crc
near-end-hec
far-end-fec
Stinger® MRT Getting Started Guide
Checking the status of an ADSL-DMT interface
Setting
Indicates how long the interface has been up (days, hours,
and minutes in {dd hh mm} format).
Indicates whether the interface is receiving (yes) or not
receiving (no) a signal from the CPE.
Indicates the number of times the link has changed from an
UP state to a DOWN state since the unit was last reset.
Indicates whether the port has passed the modem chipset
self-test.
Indicates current downstream noise margin in decibels.
Indicates current downstream attenuation in decibels.
Indicates current downstream aggregate power level in
dBm.
Indicates current upstream noise margin in decibels.
Indicates current upstream attenuation in decibels.
Indicates current upstream aggregate power level in dBm.
Indicates forward error correction (FEC) errors detected by
the COE ADSL transceiver unit (ATU).
Indicates cyclic redundancy check (CRC) errors detected by
the COE ATU.
Indicates header error control (HEC) errors detected by the
COE ATU.
Indicates forward error correction (FEC) errors detected by
the CPE ATU.
Configuring the ADSL Line Interfaces