admin> write
IMAGROUP/ima1 written
2
Assign unique nailed group numbers to each of the DS1 lines.
admin> read ds1-atm {1 18 1}
DS1-ATM/{ shelf-1 trunk-module-2 1 } read
admin> set line-config nailed-group = 851
admin> write
DS1-ATM/{ shelf-1 trunk-module-2 1 } written
admin> read ds1-atm {1 18 2}
DS1-ATM/{ shelf-1 trunk-module-2 2 } read
admin> set line-config nailed-group = 852
admin> write
DS1-ATM/{ shelf-1 trunk-module-2 2 } written
admin> read ds1-atm {1 18 3}
DS1-ATM/{ shelf-1 trunk-module-2 3 } read
admin> set line-config nailed-group = 853
admin> write
DS1-ATM/{ shelf-1 trunk-module-2 3 } written
3
Disable and re-enable the individual DS1 lines.
admin> read ds1-atm {1 18 1}
DS1-ATM/{ shelf-1 trunk-module-2 1 } read
admin> set enable = no
admin> write
admin> set enable = yes
admin> write
DS1-ATM/{ shelf-1 trunk-module-2 1 } written
admin> read ds1-atm {1 18 2}
DS1-ATM/{ shelf-1 trunk-module-2 2 } read
admin> set enable = no
admin> write
admin> set enable = yes
admin> write
DS1-ATM/{ shelf-1 trunk-module-2 2 } written
admin> read ds1-atm {1 18 3}
DS1-ATM/{ shelf-1 trunk-module-2 3 } read
admin> set enable = no
admin> write
admin> set enable = yes
admin> write
DS1-ATM/{ shelf-1 trunk-module-2 3 } written

Considerations for assigning a nailed group number to a DS1-ATM profile

When configuring a UNI port or an IMA group, consider the following:
When you configure physical lines as UNI ports, be sure to assign unique nailed
group numbers to the corresponding ds1-atm profiles.
Stinger® MRT Getting Started Guide
Configuring T1 and E1 Trunk Modules
Configuring T1 or E1 module connections