Note
ascend-link-down-trap-enabled and ascend-link-up-trap-enabled are set to no,
the system generates linkDown and linkUp traps in all scenarios.
Modified traps to include shelf numbers
Several traps have been modified to include the value of the shelf number along
with the slot index for events such as a card reset, slot state change, system clock
change, flash state change, CAC failure, or ATM OAM loopback timeout. In
addition, new traps have been introduced for events and state changes on remote
shelves.
Enabling remote shelf watchdog warning traps
To enable the system to send traps related to sensors on remote shelves, the
following parameters must be set to yes (their default value):
[in TRAP/""]
remote-shelf-enabled = yes
watchdog-warning-enabled = yes
Remote shelf watchdog profiles are created and deleted on the host depending on
the operational state of the remote-shelf-stat profile for that shelf. These
profiles are indexed using the shelf-number x 1000 + the unit value on the
remote shelf. For example,
4001 = 4 x 1000 + 1
For example:
HOST> dir watchdog
Stinger® MRT Getting Started Guide
LinkUp and LinkDown traps are not generated unless
ascend-link-down-trap-enabled and ascend-link-up-trap-enabled are set
to no.
AscendLinkUp traps are not generated in the case of slots coming up and
system reset. In these cases, the ascendLinkUp trap will not be sent for 120
seconds after the slot comes up.
AscendLinkDown traps are not generated in the case of slots going down.
The sysSlotStateChange trap is generated only for the slot status changes to
operStateDown or operStateUp. The trap is not sent for other intermediate
states such as operStateLoading and operStatePost.
If trap-optimization-enabled is set to yes but slot-enabled is set to no, the
system generates ascendLinkDown and ascendLinkUp traps for each line
when a slot changes state, and does not generate the sysSlotStateChange
trap.
If trap-optimization-enabled is set to yes but
68 11/06/2003 11:59:46 { thermal shelf-controller 1 }
41 11/06/2003 11:59:53 { relay cm-input-relay 1 }
41 11/06/2003 11:59:53 { relay cm-input-relay 2 }
41 11/06/2003 11:59:53 { relay cm-input-relay 3 }
68 11/06/2003 11:59:46 { thermal shelf-controller 4001 }
33 11/06/2003 00:24:08 { relay cm-input-relay 4001 }
33 11/06/2003 00:22:27 { relay cm-input-relay 4002 }
33 11/06/2003 00:22:27 { relay cm-input-relay 4003 }
Hosted Operation of Cascaded Stinger MRT units
Hosted MRT system management
B-21