Figure 6-8. Management connection from a remote network
LINE 1-24
SEE INSTRUCTION MANUAL
SIEHE ANLEITUNG
LIRE LE MANUEL d'INSTRUCTION
USE OF RING LUGS RECOMMENDED
Figure 6-8 shows the IP address of 1.1.1.128/24 assigned to the Stinger MRT.
Sample Stinger MRT configuration
In Figure 6-8, the connection from the Stinger MRT to the DSLTNT® unit uses an
OC3-ATM interface. The following commands create a local connection profile and
specify the IP address of the DSLTNT® unit:
admin> new connection dsltnt-1
CONNECTION/dsltnt-1 read
admin> set active = yes
admin> set encapsulation-protocol = atm
admin> set ip-options remote-address = 3.3.3.3/24
The following commands specify the AAL5 multiplexing method and assign VCI 101
to the link:
admin> set atm-options atm1483type = aal5-llc
admin> set atm-options vci = 101
The following commands display the nailed-group number of the OC3 trunk
interface (trunk module 1, port 2) and assign it to the PVC:
admin> which -n {1 18 2}
Nailed group corresponding to port { shelf-1 trunk-module-1 1 } is 802
admin> set atm-options nailed-group = 852
The following commands assign an upstream and downstream quality of service
(QoS) contract and write the profile:
admin> set atm-qos-options usr-up-stream-contract = cbr
admin> set atm-qos-options usr-dn-stream-contract = cbr
admin write
CONNECTION/dsltnt-1 read
Stinger® MRT Getting Started Guide
Configuring Administrative Access, System Timing, and Startup Settings
1.1.1.128/24
POTS
SHELF
ALARM RELAY
MINOR
CONSOLE
ETHERNET 10BT
EXP1
EXP2
STATUS
GROUP
PORT
1
5
6
10
PORTS
SELECT
BITS
ID
MAJOR
MODEM
LINE 25-48
Additional administrative connections and configuration
ATM
SD
SD
LOS
LOS
PORT 1
PORT 2
POTS 25-48
POTS 1-24
3.3.3.3/24
Management
workstation