Parameter
max-rate
gshdsl-standard-
network-type
annexb-anfp-
enabled
Stinger® MRT Getting Started Guide
Setting
Maximum rate at which the modem trains when rate-mode
is set to auto. When rate-mode is set to fixed, the modem
attempts to train only to the rate specified by this
parameter. You need only configure the central office
equipment (COE) for the maximum rate value. The modem
uses a G.994.1 handshake protocol to communicate the
maximum rate value to the customer premises equipment
(CPE).
72000
136000
200000
264000
328000
392000
520000
776000
1032000
1160000
1288000
1544000
2056000
2312000 (the default)
The G.991.2 standard network type for the network that is
connected to the SHDSL port. This setting specifies the modem
output characteristics for either a North American or
European network. Specify one of the following values:
north-american-annex-a—North American Annex A
network.
european-annex-b—European Annex B network.
auto-detect—Select network type automatically. This
value is valid only if unit-type is CPE.
Special test parameter for internal test purposes. Leave at
default value of no.
Configuring the SHDSL line interfaces
Configuring SHDSL interfaces
8-7