Configuring the ADSL Line Interfaces
Configuring ATM ADSL-DMT interfaces
bit-swapping = no
fbm-dbm-mode = fbm
alcatel-us-413-boost = unknown
Parameter
nailed-group
vp-switching-vpi
line-code
line-latency-down
line-latency-up
trellis-encoding
upstream-start-bin
upstream-end-bin
downstream-start-
bin
7-4
Setting
Specifies the nailed-group number for the ADSL-DMT
physical interface. A Connection or RADIUS profile uses
this number to specify the interface.
Because each interface is assigned a unique default
number, you do not need to modify the value of this
parameter. If you assign a new value, it must be a number
from 1 to 1024 that is unique within the system.
Specifies the virtual path identifier (VPI) to use for virtual
path (VP) switching on the DSL port. The default is 15. All
other VPIs are used for virtual channel (VC) switching.
Specifies the DMT line code to be used for training. Valid
values are auto-select
,
default value is auto-select, which enables automatic
detection of the ADSL line coding.
Specifies the latency path (fast or interleave) to be used
for downstream data transport. The default value is
interleave for G.lite and fast for all other line protocols.
For related settings, see "Fast and interleaved bit-rate
parameters" on page 7-7.
Specifies the latency path (fast or interleave) to be used
for upstream data transport. Default value is
for G.lite and
for all other line protocols.
fast
For related settings, see "Fast and interleaved bit-rate
parameters" on page 7-7.
Enable/disable trellis encoding. Trellis encoding is
specified in the DMT standard. Disabling this parameter
(no) can increase performance, but at the cost of
becoming noncompliant with the standard. The default is
yes.
Specifies the starting frequency interval (or bin) for
upstream transmission. The valid range is 0 to 31. The
default value is 6.
Specifies the ending frequency bin for upstream
transmission. The valid range is 0 to 31. The default value
is 31.
Specifies the starting frequency bin for downstream
transmission. The valid range is 32 to 255. The default
value is 32.