Configuring the SHDSL line interfaces
Configuring SHDSL interfaces
Parameter
gshdsl-psd-type
master-binding-
port
8-8
Setting
The SHDSL Stinger MRT outputs a symmetric power spectral
density (PSD), based on the G.shdsl standard G.991.2.
Specify one of the following values:
symmetric—The modem outputs a symmetric power
spectral density for all rates.
asymmetric-776k-psd—The modem outputs an
asymmetric power spectral density at 776Kbps only.
This setting applies only if the rate-mode parameter is
set to fixed, the max-rate parameter is set to is 776000,
and the network-type parameter is set to
north-american-annex-a.
asymmetric-1544k-psd—The modem outputs an
asymmetric power spectral density at 1544Kbps only.
This setting applies only if the rate-mode parameter is
set to fixed, the max-rate parameter is set to is 1544000,
and the network-type parameter is set to
north-american-annex-a.
asymmetric-2056k-psd—The modem outputs an
asymmetric power spectral density at 2056Kbps only.
This setting applies only if the rate-mode parameter is
set to fixed, the max-rate parameter is set to is 2056000,
and the network-type parameter is set to
european-annex-b.
asymmetric-2312k-psd—The modem outputs an
asymmetric power spectral density at 2312Kbps only.
This setting applies only if the rate-mode parameter is
set to fixed, the max-rate parameter is set to is 2312000,
and the network-type parameter is set to
european-annex-b.
automatic—Select network type automatically. This
value is valid only if unit-type is CPE
Specifies whether an SHDSL port is configured for binding
to the next adjacent port. Binding two SHDSL ports
together aggregates their bandwidths together.
Binding is enabled by configuring an odd numbered port as
master. The next even numbered port is bound to the
master port. The rate-mode parameter must be set to fixed.
The enabled parameter must be set to yes for both ports.
The master ports max-rate and rate-mode parameter values
are used for both ports.
Specify one of the following values for master-binding-port
parameter:
no—Do not set the port to master binding port.
yes—Set the port to master binding port.