Imahw-Config Profile - Lucent Technologies Stinger MRT 19 Getting Started Manual

Table of Contents

Advertisement

Configuring T1 and E1 Trunk Modules

IMAHW-Config profile

Parameter
tpp-state
vp-switching-vpi

IMAHW-Config profile

Following are the parameters for the IMAHW-Config profile, shown with sample
settings:
[in IMAHW-CONFIG/{ shelf-1 slot-18 1 }]
name = 1:18:1
physical-address* = { shelf-1 slot-18 1 }
alpha-ima-value = 2
beta-ima-value = 2
gamma-ima-value = 1
alpha-cell-delin-value = 7
delta-cell-delin-value = 6
..
Parameter
name
physical-address
alpha-ima-value
9-20
Setting
Enables or disables the test pattern procedure.
Valid values are as follows:
disabled—Test pattern procedure is currently disabled
on this link.
operating—Test pattern procedure is currently
operating on this link.
Specifies the virtual path identifiers (VPIs) that the
system uses for VP switching on the DS1-ATM port.
Specify a VPI from 1 through 31. The default is 15.
Setting
Assigns a name to a profile, interface, user, route, host,
module, or the Stinger MRT system itself. Specify a
descriptive name with no embedded spaces.
Identifies the physical address of an interface.
The physical address has the format {shelf slot item}.
shelf is the shelf in which the item resides. Since a
Stinger MRT unit is a single-shelf system, the shelf
number is always 1.
slot is the number of the item's expansion slot. The
slot number for the trunk module in the Stinger MRT is
18.
item is the item on the module. An item number of 1
(one) denotes the entire slot.
Specifies the alpha value of consecutive invalid IMA
Control Protocol (ICP) cells to be detected before the line
changes to the IMA HUNT state from the SYNC state.
Specify the number 1 or the number 2.