Configuring a DS3-ATM Trunk Module
Configuring a DS3-ATM trunk module
spare-physical-address = { any-shelf any-slot 0 }
sparing-mode = inactive
[in DS3-ATM/{ shelf-1 trunk-module-2 1 }:line-config]
trunk-group = 9
nailed-group = 851
activation = static
call-route-info = { any-shelf any-slot 0 }
loopback = no-loopback
high-tx-output = no
framer-mode = C-BIT-PLCP
receive-equalization = no
vpi-vci-range = vpi-0-255-vci-32-8191
vc-switching-vpi = [ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ]
clock-source = not-eligible
clock-priority = middle-priority
cell-payload-scramble = yes
status-change-trap-enable = no
Parameter
name
physical-address
enabled
spare-physical-addre
ss
sparing-mode
line-config:trunk-
group
line-config:nailed-
group
line-config:
activation
line-config:call-
route-info
line-config:loopback Enable/disable loopback for diagnosing connectivity or
11-4
Setting
Name of the interface. The default value is the interface
address in shelf:slot:item format (for example, 1:18:2), but
you can assign a text string of up to 16 characters.
Physical address of the trunk port in the Stinger unit.
Enable/disable the DS3-ATM interface, which is disabled by
default.
Physical address of the trunk port to be used as a spare.
Redundancy mode for the port.
Not currently used. Leave the default value (zero).
Nailed-group number for the DS3-ATM physical interface.
A Connection or RADIUS profile specifies this number to
make use of the interface.
Each interface is assigned a unique default number, so you
do not need to modify this parameter. If you assign a new
value, it must be a number from 1 to 1024 that is unique
within the system. See "Displaying DS3-ATM port status
and nailed groups" on page 11-5 for related information.
Line activation mode. Only the static setting is currently
supported.
Not currently used. Leave the default value (the zero address).
possible equipment problems. Loopback is disabled by
default, which is required for normal operations.