Certifications; Minimum Ground Wire Size; Physical Specifications; Table D-4 Stinger Mrt Minimum Ground Wire Sizes - Lucent Technologies Stinger MRT 19 Getting Started Manual

Table of Contents

Advertisement

Safety-Related Electrical, Physical, and Environmental Information

Physical specifications

VCCI Class A
CISPR 22 Class A
EN 3003386-2

Certifications

The Stinger MRT meets the following certifications:
NEBS 1-3
Telcordia GR-63-CORE
Telcordia GR-1089-CORE

Minimum ground wire size

The DSL lines coming into the Stinger MRT can be subject to lightning surges. These
must be discharged to ground through an adequate ground wire. An adequate
ground wire presents a resistance of approximately 0.02ohms to a surge of 500 amps.
The gauges shown in Table D-4 are appropriate for the wire lengths indicated:
Table D-4. Stinger MRT minimum ground wire sizes
Length
0 to 10 feet (0m to 3.05m)
10 to 25 feet (3.05m to 7.62m)
25 to 50 feet (7.62m to 15.24m)
50 to 100 feet (15.24m to 30.48m)
Lucent Technologies does not recommend a ground wire greater than 100 feet long.
Physical specifications
Table D-5 describes the Stinger MRT physical specifications.
Table D-5. Stinger MRT physical specifications
Specification
ATM standards
WAN interfaces
Management interfaces
Physical characteristics
D-4
Wire gauge
12 AWG (3.31mm²)
9 AWG (6.63mm²)
6 AWG (13.3mm²)
3 AWG (26.7mm²)
Description
ATM Forum UNI (Version 3.0 and Version 3.1), ATM
Forum Interim Interswitch Signaling Protocol (IISP)
DS3 and E3 (cell-based), OC3c/STM-1 (optical and
electrical), T1, E1, and Ethernet
Ethernet and RS-232
Basic unit includes integrated dc power filters and
cooling fan.
Stinger® MRT Getting Started Guide