Chapter 2 Command System
:SINGle
Syntax
:SINGle
Description
Sets the trigger mode of the oscilloscope to "Single". This command functions the same as
either of the following two operation: press SINGLE on the front panel; or send
the
:TRIGger:SWEep SINGle
Remarks
In the single trigger mode, the oscilloscope performs a single trigger when the trigger
conditions are met and then it stops.
When the waveform recording function is enabled or the recorded waveforms are
played back, this command is invalid.
For the single trigger, you can use the
force.
:TFORce
Syntax
:TFORce
Description
Generates a trigger signal forcefully. This command is only applicable to the normal and
single trigger modes (refer to the
the same as the FORCE key in the trigger control area of the front panel.
MSO7000/DS7000 Programming Guide
command.
:TFORce
:TRIGger:SWEep
command to generate one trigger by
command). This command functions
RIGOL