Rigol DS7034 User Programming Manual page 198

Mso7000 series; ds7000 series; digital oscilloscope
Hide thumbs Also See for DS7034:
Table of Contents

Advertisement

RIGOL
:TRIGger:RUNT:WLOWer
Syntax
:TRIGger:RUNT:WLOWer <width>
:TRIGger:RUNT:WLOWer?
Description
Sets or queries the lower limit of the pulse width of Runt trigger. The default unit is s.
Parameter
Name
<width>
Remarks
This command is only available when the qualifier is set to GREater or GLESs.
When the qualifier is set to "GLESs", the lower limit of the pulse width must be
smaller than the upper limit of the pulse width.
Return
The query returns the lower limit of the pulse width in scientific notation.
Format
Example
:TRIGger:RUNT:WLOWer 0.01
:TRIGger:RUNT:WLOWer?
:TRIGger:RUNT:ALEVel
Syntax
:TRIGger:RUNT:ALEVel <level>
:TRIGger:RUNT:ALEVel?
Description
Sets or queries the upper limit of the trigger level of Runt trigger. The unit is the same
as that of the current amplitude.
Parameter
Name
<level>
Remarks
For VerticalScale, refer to the
the
:CHANnel<n>:OFFSet
Return
The query returns the upper limit of the trigger level in scientific notation.
Format
Example
:TRIGger:RUNT:ALEVel 0.16
:TRIGger:RUNT:ALEVel?
:TRIGger:RUNT:BLEVel
Syntax
:TRIGger:RUNT:BLEVel <level>
:TRIGger:RUNT:BLEVel?
Description
Sets or queries the lower limit of the trigger level of Runt trigger. The unit is the same
as that of the current amplitude.
Parameter
Name
<level>
Remarks
For VerticalScale, refer to the
the
Return
The query returns the lower limit of the trigger level in scientific notation.
Format
Example
:TRIGger:RUNT:BLEVel 0.16
:TRIGger:RUNT:BLEVel?
2-184
Type
Range
8 ns to 9.9 s
Real
Type
Range
Real
Lower limit to (5 × VerticalScale - OFFSet)
command.
Type
Range
Real
(-5 × VerticalScale - OFFSet) to upper limit
:CHANnel<n>:OFFSet
/*Sets the lower limit of the pulse width to 10 ms.*/
/*The query returns 1.000000E-2.*/
:CHANnel<n>:SCALe
/*Sets the upper limit of the trigger level to 160 mV.*/
/*The query returns 1.600000E-1.*/
:CHANnel<n>:SCALe
command.
/*Sets the lower limit of the trigger level to 160 mV.*/
/*The query returns 1.600000E-1.*/
Chapter 2 Command System
Default
8 ns
Default
0 V
command; for OFFSet, refer to
Default
0 V
command; for OFFSet, refer to
MSO7000/DS7000 Programming Guide