Bus<N>:Flexray (Option) - Rigol DS7034 User Programming Manual

Mso7000 series; ds7000 series; digital oscilloscope
Hide thumbs Also See for DS7034:
Table of Contents

Advertisement

Chapter 2 Command System
:BUS<n>:FLEXray (Option)
The :BUS<n>:FLEXray commands are used to set the relevant parameters for FLEXray decoding.
Command List:
:BUS<n>:FLEXray:BAUD
:BUS<n>:FLEXray:SOURce
:BUS<n>:FLEXray:SPOint
:BUS<n>:FLEXray:STYPe
:BUS<n>:FLEXray:BAUD
Syntax
:BUS<n>:FLEXray:BAUD <baud>
:BUS<n>:FLEXray:BAUD?
Description
Sets or queries the signal rate of FlexRay decoding. The default unit is bps.
Parameter
Name
<n>
<baud>
Return
The query returns 2500000, 5000000, or 10000000.
Format
Example
:BUS1:FLEXray:BAUD 2500000
:BUS1:FLEXray:BAUD?
:BUS<n>:FLEXray:SOURce
Syntax
:BUS<n>:FLEXray:SOURce <source>
:BUS<n>:FLEXray:SOURce?
Description
Sets or queries the source channel of FlexRay decoding.
Parameter
Name
<n>
<source>
Return
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14,
Format
D15, CHAN1, CHAN2, CHAN3, or CHAN4.
Example
:BUS1:FlexRay:SOURce D0
:BUS1:FlexRay:SOURce?
MSO7000/DS7000 Programming Guide
Type
Range
Discrete
{1|2|3|4}
Discrete
{2500000|5000000|10000000}
/*Sets the signal rate of FlexRay decoding to
2500000 bps.*/
/*The query returns 2500000.*/
Type
Range
Discrete
{1|2|3|4}
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|
Discrete
D12|D13|D14|D15|CHANnel1|CHANnel2|CHAN
nel3|CHANnel4}
/*Sets the source channel of FlexRay decoding to D0.*/
/*The query returns D0.*/
RIGOL
Default
——
10000000
Default
——
CHANnel1
2-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7054Ds7024Ds7014Mso7034Mso7024Mso7014 ... Show all

Table of Contents