Power:voltagesource; Power:quality:freqreference; Power:reflevel:method - Rigol DS7034 User Programming Manual

Mso7000 series; ds7000 series; digital oscilloscope
Hide thumbs Also See for DS7034:
Table of Contents

Advertisement

RIGOL

:POWer:VOLTagesource

Syntax
:POWer:VOLTagesource <source>
:POWer:VOLTagesource?
Description
Sets or queries the voltage source of power quality.
Parameter
Name
<source>
Return
The query returns CHAN1, CHAN2, CHAN3, or CHAN4.
Format
Example
:POWer:VOLTagesource CHANnel2
:POWer:VOLTagesource?

:POWer:QUALity:FREQREFerence

Syntax
:POWer:QUALity:FREQREFerence <source>
:POWer:QUALity:FREQREFerence?
Description
Sets or queries the frequency reference source of power quality.
Parameter
Name
<source>
Return
The query returns VOLT or CURR.
Format
Example
:POWer:QUALity:FREQREFerence CURRent
:POWer:QUALity:FREQREFerence?

:POWer:REFLevel:METHod

Syntax
:POWer:REFLevel:METHod <method>
:POWer:REFLevel:METHod?
Description
Sets or queries the reference level type of power quality.
Parameter
Name
<method>
Return
The query returns ABS or PERC.
Format
Example
:POWer:REFLevel:METHod ABSolute
:POWer:REFLevel:METHod?
2-118
Type
Range
Discrete
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
Type
Range
Discrete
{VOLTage|CURRent}
Type
Range
Discrete
{ABSolute|PERCent}
/*Sets the voltage source to CH2.*/
/*The query returns CHAN2.*/
/* Sets the frequency reference source of
power quality to CURRent.*/
/*The query returns CURR.*/
/*Sets the reference level type of power quality
to ABSolute.*/
/*The query returns ABS.*/
MSO7000/DS7000 Programming Guide
Chapter 2 Command System
Default
CHANnel1
Default
VOLTage
Default
PERCent

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7054Ds7024Ds7014Mso7034Mso7024Mso7014 ... Show all