Rigol DS7034 User Programming Manual page 201

Mso7000 series; ds7000 series; digital oscilloscope
Hide thumbs Also See for DS7034:
Table of Contents

Advertisement

Chapter 2 Command System
:TRIGger:WINDows:BLEVel
Syntax
:TRIGger:WINDows:BLEVel <level>
:TRIGger:WINDows:BLEVel?
Description
Sets or queries the lower limit of the trigger level of Window trigger. The unit is the
same as that of the current amplitude.
Parameter
Name
<level>
Remarks
For VerticalScale, refer to the
the
:CHANnel<n>:OFFSet
Return
The query returns the lower limit of the trigger level in scientific notation.
Format
Example
:TRIGger:WINDows:BLEVel 0.05 /*Sets the lower limit of the trigger level to 50 mV.*/
:TRIGger:WINDows:BLEVel?
MSO7000/DS7000 Programming Guide
Type
Range
Real
(-5 × VerticalScale - OFFSet) to upper limit
:CHANnel<n>:SCALe
command.
/*The query returns 5.000000E-2.*/
Default
0 V