  • Page 2 • RIGOL products are covered by P.R.C. and foreign patents, issued and pending. • RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at the company's sole decision. • Information in this publication replaces all previously released materials.
  • Page 3: Safety Requirement

    Safety Terms on the Product: • DANGER It calls attention to an operation, if not correctly performed, could result in injury or hazard immediately. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 4: Care And Cleaning

    To avoid damage to the instrument, do not expose it to caustic liquids. Warning To avoid short-circuit resulting from moisture or personal injuries, ensure that the instrument is completely dry before connecting it to the power supply. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 5: Document Overview

    This manual gives you a quick review about the front and rear panel of DS70000 series, the user interface, and the basic operation method. http:// For the latest version of this manual, download it from the official website of RIGOL ( www.rigol.com Publication Number...
  • Page 6: General Inspection

    The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument. 2 Inspect the instrument In case of any mechanical damage,missing parts, or failure in passing the electrical and mechanical tests, contact your RIGOL sales representative.
  • Page 7: Product Overview

    Product Overview Product Overview DS70000 series is RIGOL's 7th generation of the digital oscilloscope. It adopts RIGOL's chipset "Phoenix", delivering excellent performance with a maximum sample rate of 20 GSa/s, 5 GHz real-time bandwidth. In addition to the improvement of hardware specification, DS70000 series also has many user-friendly designs to ensure high- quality user experience.
  • Page 8: Rear Panel Overview

    10 MHz IN Reference Clock Input unavailable) Pulse Source Output (temporally USB DEVICE Interface unavailable) Pulse Source Reverse Output USB HOST Interface (temporally unavailable) Pulse Source Reverse Input LAN Interface (temporally unavailable) Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 9: User Interface

    Trigger Label Channel Operation Label Horizontal Position Label RTSA Label Sample Rate and Memory Depth Label Multi-window Display Area Horizontal Time Base Label Notification Area Operating Status Result Display Window Waveform Display Area Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 10: To Prepare For Use

    During the start-up process, the instrument performs a series of self-tests. After the self-test, the splash screen is displayed. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 11: To Set The System Language

    > Utility > Setup > Language to set the system language. To Connect the Probe RIGOL provides passive and active probes for DS70000 series. For specific probe Datasheet . For detailed technical information of the models, please refer to DS70000 probes, please refer to the corresponding Probe User Guide.
  • Page 12 ". To Connect the Active Probe Take PVA8000 (active differential probe) as an example. 1 Connect the probe head to the preamp of the active probe, as shown in the figure below. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 13 Note that you need to push the probe to the due position to lock it firmly. Figure 5.4 To Connect the Active Probe Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 14: Function Inspection

    4 Set the probe attenuation to 10X, and then click > Auto. 5 Observe the waveform on the display. In normal condition, the square waveform as shown in the figure below should be displayed. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 15: Probe Compensation

    Function Inspection 1 Perform Step 1, 2, 3 and 4 specified in " ". 2 Check the displayed waveforms and compare them with the waveforms shown in Figure 5.7 Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 16 3 Use the probe compensation adjustment tool provided in the accessories to adjust the low-frequency compensation adjustment hole on the probe until the displayed waveform is consistent with the "Perfectly compensated" waveform shown in the above figure. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 17: Touchscreen Gestures

    Use one finger to select the object, and then drag the object to a destination place, as Figure 6.2 shown in . With the drag gesture, you can perform the following operation: Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 18 • Pinching&stretching in the horizontal direction can adjust the horizontal time base of the waveform. • Pinching&stretching in the vertical direction can adjust the vertical scale of the waveform. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 19 Touch Screen Gestures Figure 6.3 Pinch&Stretch Gesture Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 20: To Use The Built-In Help System

    > Help to enter the help system. Figure 7.1 Help Information After opening the help interface, you can get its help information by clicking on or tapping the link for the desired item. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 21: Parameter Setting Method

    • Deletes the parameter value that has been input; • Sets the parameter value to a maximum or minimum value; • Sets the parameter to a default value; Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 22 Parameter Setting Method • Clears the parameter value. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 23: Fuse Replacement

    Warning To avoid electric shock, please ensure that the instrument has been turned off, the power source has been cut off, and the fuse to be used conforms to the fuse rating. Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
  • Page 24: Remote Control

    SCPI (Standard Commands for Programmable Instruments) commands. This chapter will illustrate how to use the to work with RIGOL Ultra Sigma software to remotely control the instrument via various interfaces. Note: When communicating with the PC via GPIB, the instrument does not support large data transmission operation such as screen shot and waveform reading.
  • Page 25: More Product Information

    User Guide. For more information about this instrument, refer to the relevant manuals by logging http://www.rigol.com in to the official website of RIGOL ( ) to download them. User Guide : introduces the functions of the instrument and the •...