RIGOL
:TRIGger:SPI:TIMeout
Syntax
:TRIGger:SPI:TIMeout <time>
:TRIGger:SPI:TIMeout?
Description
Sets or queries the timeout value when the trigger condition of SPI trigger is
"Timeout". The default unit is s.
Parameter
Name
<time_value>
Return
The query returns the timeout value in scientific notation.
Format
Example
:TRIGger:SPI:TIMeout 0.001
:TRIGger:SPI:TIMeout?
:TRIGger:SPI:SLOPe
Syntax
:TRIGger:SPI:SLOPe <slope>
:TRIGger:SPI:SLOPe?
Description
Sets or queries the type of the clock edge of SPI trigger.
Parameter
Name
<slope>
Remarks
POSitive: samples the SDA data on the rising edge of the clock.
NEGative: samples the SDA data on the falling edge of the clock.
Return
The query returns POS or NEG.
Format
Example
:TRIGger:SPI:SLOPe POSitive
:TRIGger:SPI:SLOPe?
:TRIGger:SPI:CLEVel
Syntax
:TRIGger:SPI:CLEVel <level>
:TRIGger:SPI:CLEVel?
Description
Sets or queries the trigger level of the clock channel of SPI trigger. The unit is the
same as that of the current amplitude.
Parameter
Name
<level>
Remarks
For VerticalScale, refer to the
the
:CHANnel<n>:OFFSet
Return
The query returns the trigger level in scientific notation.
Format
Example
:TRIGger:SPI:CLEVel 0.16
:TRIGger:SPI:CLEVel?
2-210
Type
Range
Real
16 ns to 1 s
/*Sets the timeout value to 1 ms.*/
/*The query returns 1.000000E-3.*/
Type
Range
Discrete
{POSitive|NEGative}
/*Sets the clock edge to POSitive.*/
/*The query returns POS.*/
Type
Range
(-5 × VerticalScale - OFFSet) to
Real
(6 × VerticalScale - OFFSet)
:CHANnel<n>:SCALe
command.
/*Sets the trigger level to 160 mV.*/
/*The query returns 1.600000E-1.*/
Chapter 2 Command System
Default
1 μs
Default
POSitive
Default
0 V
command; for OFFSet, refer to
MSO7000/DS7000 Programming Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7054Ds7024Ds7014Mso7034Mso7024Mso7014 ... Show all