Chapter 2 Command System
:TRIGger:DURATion:TLOWer
Syntax
:TRIGger:DURATion:TLOWer <time>
:TRIGger:DURATion:TLOWer?
Description
Sets or queries the lower limit of the duration time of Duration trigger. The default unit
is s.
Parameter
Name
<time>
Remarks
This command is only available when the trigger conditions are GREater and GLESs.
Return
The query returns the lower limit of the duration time in scientific notation.
Format
Example
:TRIGger:DURATion:TLOWer 0.000003 /*Sets the lower limit of the duration time to
:TRIGger:DURATion:TLOWer?
:TRIGger:DURation:LEVel
Syntax
:TRIGger:DURation:LEVel <source>,<level>
:TRIGger:DURation:LEVel? <source>
Description
Sets or queries the trigger level of the specified channel in Duration trigger. The unit is
the same as that of the current amplitude.
Parameter
Name
<source>
<level>
Remarks
For VerticalScale, refer to the
the
:CHANnel<n>:OFFSet
Return
The query returns the trigger level in scientific notation.
Format
Example
:TRIGger:DURation:LEVel CHANnel2,0.16 /*Sets the trigger level of CH2 to 160 mV.*/
:TRIGger:DURation:LEVel? CHANnel2
MSO7000/DS7000 Programming Guide
Type
Range
Real
800 ps to 10 s
Type
Range
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D
Discrete
11|D12|D13|D14|D15|CHANnel1|CHANnel2
|CHANnel3|CHANnel4}
(-5 × VerticalScale - OFFSet) to (5 ×
Real
VerticalScale - OFFSet)
:CHANnel<n>:SCALe
command.
3 μs.*/
/*The query returns 3.000000E-6.*/
command. For OFFSet, refer to
/*The query returns 1.600000E-1.*/
RIGOL
Default
1 μs
Default
CHANnel1
0 V