RIGOL
:TRIGger:SPI:CS
Syntax
:TRIGger:SPI:CS <source>
:TRIGger:SPI:CS?
Description
Sets or queries the source channel of the CS line when the trigger condition of SPI
is set to CS.
Parameter
Name
<source>
Return
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13,
Format
D14, D15, CHAN1, CHAN2, CHAN3, or CHAN4.
Example
:TRIGger:SPI:CS CHANnel2
/*Sets source channel of the CS line when the trigger condition of SPI is set to CS
to CH2.*/
:TRIGger:SPI:CS?
2-212
Type
Range
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D
Discrete
11|D12|D13|D14|D15|CHANnel1|CHANnel2
|CHANnel3|CHANnel4}
/*The query returns CHAN2.*/
Chapter 2 Command System
Default
CHANnel3