Chapter 2 Command System

:SYSTem:OPTion:STATus?

Syntax
:SYSTem:OPTion:STATus? <type>
Description
Queries the status of the options of the oscilloscope.
Parameter
Name
<type>
Return
The query returns 0 or 1.
Format
0: indicates that the option is not installed.
1: indicates that the official option has been installed.

:SYSTem:RAMount?

Syntax
:SYSTem:RAMount?
Description
Queries the number of analog channels of the current instrument.
Return
The query returns the number of analog channels of the current instrument in integer. For
Format
this oscilloscope, the query returns a fixed value 4.

:SYSTem:RESet

Syntax
:SYSTem:RESet
Description
Resets the system to power on again.

:SYSTem:SETup

Syntax
:SYSTem:SETup <setup_data>
:SYSTem:SETup?
Description
Sends or reads the data stream of the system setup file.
Parameter
Name
<setup_data>
Remarks
<setup_data> is a binary data block, which consists of the TMC data block
header and setup data.
When sending the command, directly place the data stream after the
command string, then complete the whole sending process in one time. When
reading the data stream, ensure that there is enough buffer space to receive
the data stream; otherwise, errors might occur in reading the program.
MSO7000/DS7000 Programming Guide
Type
Discrete
Type
ASCII String
The format of the TMC data block header is #NX...X. Wherein, # is the
start identifier of the data stream; the N-digit data "X...X" (N≤9)
following the start identifier indicate the length of the data stream (the
number of bytes).
For example, #9000002506.
Wherein, N is 9, 000002506 following it represents that the data stream
contains 2506 bytes of effective data.
The setup data are expressed in ASCII format.
Range
{BW12|BW13|BW15|BW23|BW2
5|BW35|MSO|RL2|RL5|BND|CO
MP|EMBD|AUTO|AUDIO|SENSO
R|AERO|ARINC|DG|JITTer|MAS
K|PWR|DVM|CTR|EDK}
Range
Refer to
Remarks
RIGOL
Default
——
Default
——
2-155

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7054Ds7024Ds7014Mso7034Mso7024Mso7014 ... Show all

Table of Contents