RIGOL
:TRIGger:SHOLd:STIMe
Syntax
:TRIGger:SHOLd:STIMe <time>
:TRIGger:SHOLd:STIMe?
Description
Sets or queries the setup time of Setup&Hold trigger. The default unit is s.
Parameter
Name
<time>
Remarks
Setup time indicates the time that the data remain stable and unchanged before
the clock signal of the trigger comes.
This command is only available when the hold type is SETup or SETHOld.
Return
The query returns the setup time value in scientific notation.
Format
Example
:TRIGger:SHOLd:STIMe 0.002
:TRIGger:SHOLd:STIMe?
:TRIGger:SHOLd:HTIMe
Syntax
:TRIGger:SHOLd:HTIMe <time>
:TRIGger:SHOLd:HTIMe?
Description
Sets or queries the hold time of Setup&Hold trigger. The default unit is s.
Parameter
Name
<time>
Remarks
Hold time indicates the time that the data remain stable and unchanged after the
clock signal of the trigger comes.
This command is only available when the hold type is HOLD or SETHold.
Return
The query returns the hold time value in scientific notation.
Format
Example
:TRIGger:SHOLd:HTIMe 0.002
:TRIGger:SHOLd:HTIMe?
:TRIGger:SHOLd:DLEVel
Syntax
:TRIGger:SHOLd:DLEVel <level>
:TRIGger:SHOLd:DLEVel?
Description
Sets or queries the trigger level of the data source. The unit is the same as that of the
current amplitude.
Parameter
Name
<level>
Remarks
For VerticalScale, refer to the
the
:CHANnel<n>:OFFSet
Return
The query returns the trigger level of the data source in scientific notation.
Format
Example
:TRIGger:SHOLd:DLEVel 0.16
:TRIGger:SHOLd:DLEVel?
2-194
Type
Range
Real
8 ns to 1 s
/*Sets the setup time to 2 ms.*/
/*The query returns 2.000000E-3.*/
Type
Range
Real
8 ns to 1 s
/*Sets the hold time to 2 ms.*/
/*The query returns 2.000000E-3.*/
Type
Range
(-5 × VerticalScale - OFFSet) to
Real
(5 × VerticalScale - OFFSet)
:CHANnel<n>:SCALe
command.
/*Sets the trigger level of the data source to 160 mV.*/
/*The query returns 1.600000E-1.*/
Chapter 2 Command System
command; for OFFSet, refer to
MSO7000/DS7000 Programming Guide
Default
1 μs
Default
1 μs
Default
0 V

Advertisement