Rigol DS7034 User Programming Manual page 205

Mso7000 series; ds7000 series; digital oscilloscope
Hide thumbs Also See for DS7034:
Table of Contents

Advertisement

Chapter 2 Command System
Return Format
The query returns the upper limit of the trigger level in scientific notation.
Example
:TRIGger:DELay:ALEVel 0.16
:TRIGger:DELay:ALEVel?
:TRIGger:DELay:BLEVel
Syntax
:TRIGger:DELay:BLEVel <level>
:TRIGger:DELay:BLEVel?
Description
Sets or queries the lower limit of the trigger level of Delay trigger. The unit is the same
as that of the current amplitude.
Parameter
Name
<level>
Remarks
For VerticalScale, refer to the
the
Return
The query returns the lower limit of the trigger level in scientific notation.
Format
Example
:TRIGger:DELay:BLEVel 0.05
:TRIGger:DELay:BLEVel?
MSO7000/DS7000 Programming Guide
Type
Range
Real
(-5 × VerticalScale - OFFSet) to upper limit
:CHANnel<n>:OFFSet
/*Sets the upper limit of the trigger level to 160 mV.*/
/*The query returns 1.600000E-1.*/
:CHANnel<n>:SCALe
command.
/*Sets the lower limit of the trigger level to 50 mV.*/
/*The query returns 5.000000E-2.*/
Default
0 V
command; for OFFSet, refer to
RIGOL
2-191

Advertisement