:TRIGger:PULSe:UWIDth
Syntax
:TRIGger:PULSe:UWIDth <width>
:TRIGger:PULSe:UWIDth?
Description
Sets or queries the pulse upper limit of the Pulse trigger. The default unit is s.
Parameter
Name
<width>
Remarks
The set upper limit cannot be smaller than the lower limit, otherwise, the lower limit
will be automatically changed.
Return
The query returns the upper limit of the pulse width in scientific notation.
Format
Example
:TRIGger:PULSe:UWIDth 0.000003 /*Sets the upper limit of the pulse width to 3 μs.*/
:TRIGger:PULSe:UWIDth?
:TRIGger:PULSe:LWIDth
Syntax
:TRIGger:PULSe:LWIDth <width>
:TRIGger:PULSe:LWIDth?
Description
Sets or queries the pulse lower limit of the Pulse trigger. The default unit is s.
Parameter
Name
<width>
Remarks
The set lower limit must be smaller than the upper limit, otherwise, the upper limit
will be automatically changed.
Return
The query returns the lower limit of the pulse width in scientific notation.
Format
Example
:TRIGger:PULSe:LWIDth 0.000003 /*Sets the lower limit of the pulse width to 3 μs.*/
:TRIGger:PULSe:LWIDth?
:TRIGger:PULSe:LEVel
Syntax
:TRIGger:PULSe:LEVel <level>
:TRIGger:PULSe:LEVel?
Description
Sets or queries the trigger level of Pulse trigger. The unit is the same as that of the
current amplitude.
Parameter
Name
<level>
Remarks
Return Format
The query returns the trigger level in scientific notation.
Example
:TRIGger:PULSe:LEVel 0.16
:TRIGger:PULSe:LEVel?
2-168
Type
Range
Real
Pulse lower limit to 10 s
Type
Range
Real
800 ps to pulse upper limit
Type
Range
(-5 × VerticalScale - OFFSet) to
Real
(5 × VerticalScale - OFFSet)
For VerticalScale, refer to the
refer to the
:CHANnel<n>:OFFSet
Only when the selected source is an analog channel or an external trigger,
can this setting command is valid.
/*The query returns 3.000000E-6.*/
/*The query returns 3.000000E-6.*/
:CHANnel<n>:SCALe
command.
/*Sets the trigger level to 160 mV.*/
/*The query returns 1.600000E-1.*/
MSO7000/DS7000 Programming Guide
Chapter 2 Command System
Default
2 μs
Default
1 μs
Default
0