RIGOL
specified user-defined channel group.
The currently enabled channel or user-defined channel group can be selected as
the active channel or the channel group by sending the
POD1: D0 to D7; POD2: D8 to D15
Return
The query returns 1 or 0.
Format
Example
:LA:DISPlay D0,ON
:LA:DISPlay? D0
:LA:POD<n>:THReshold
Syntax
:LA:POD<n>:THReshold <thre>
:LA:POD<n>:THReshold?
Description
Sets or queries the threshold of the specified default channel group. The default unit is
V.
Parameter
Name
<n>
<thre>
Remarks
2 default channel groups: POD1 (D0 to D7) or POD2 (D8 to D15).
Return
The query returns the current threshold of the specified channel group in scientific
Format
notation.
Example
:LA:POD1:THReshold 3.3
:LA:POD1:THReshold?

:LA:SIZE

Syntax
:LA:SIZE <size>
:LA:SIZE?
Description
Sets or queries the size of the waveforms of the enabled channel on the screen.
Parameter
Name
<size>
Remarks
L (large) can only be used when the number of the currently enabled channels is no
more than 8.
Return
The query returns SMAL, LARG, or MED.
Format
Example
:LA:SIZE SMALl
:LA:SIZE?
2-82
/*Enables D0.*/
/*The query returns 1.*/
Type
Range
Integer
1 to 2
Real
-20.0 V to +20.0 V
/*Sets the threshold of POD1 (D0 to D7) to 3.3 V.*/
/*The query returns 3.300000E0.*/
Type
Range
Discrete
{SMALl|LARGe|MEDium}
/*Sets the waveform display size to SMALl.*/
/*The query returns SMAL.*/
Chapter 2 Command System
:LA:ACTive
command.
Default
——
1.40V
Default
MEDium
MSO7000/DS7000 Programming Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds7054Ds7024Ds7014Mso7034Mso7024Mso7014 ... Show all

Table of Contents