RIGOL
:BUS<n>:FLEXray:SPOint
Syntax
:BUS<n>:FLEXray:SPOint <spoint>
:BUS<n>:FLEXray:SPOint?
Description
Sets or queries the sample point position of FlexRay decoding (expressed in %).
Parameter
Name
<n>
<spoint>
Remarks
Sample point is a point within a bit's time. The oscilloscope samples the bit level at this
point. The sample point position is expressed as the ratio of "time from the bit start to
the sample point" to "bit time", in %.
Return
The query returns an integer ranging from 10 to 90.
Format
Example
:BUS1:FLEXray:SPOint 70
:BUS1:FLEXray:SPOint?
:BUS<n>:FLEXray:STYPe
Syntax
:BUS<n>:FLEXray:STYPe <stype>
:BUS<n>:FLEXray:STYPe?
Description
Sets or queries the signal type of FlexRay decoding.
Parameter
Name
<n>
<stype>
Return
The query returns BP, BM, or RT.
Format
Example
:BUS1:FLEXray:STYPe BM
:BUS1:FLEXray:STYPe?
2-32
Type
Range
Discrete
{1|2|3|4}
Integer
10 to 90
/*Sets the sample point position of FlexRay decoding to
70%.*/
/*The query returns 70.*/
Type
Range
Discrete
{1|2|3|4}
Discrete
{BP|BM|RT}
/*Sets the signal type of FlexRay decoding to BM.*/
/*The query returns BM.*/
Chapter 2 Command System
Default
——
50
Default
——
BP
MSO7000/DS7000 Programming Guide