Chapter 2 Command System

:TRIGger:MODE

Syntax
:TRIGger:MODE <mode>
:TRIGger:MODE?
Description
Selects or queries the trigger type.
Parameter
Name
<mode>
Return
The query returns EDGE, PULS, SLOP, VID, PATT, DUR, TIM, RUNT, WIND, DEL, SET,
Format
NEDG, RS232, IIC, SPI, CAN, CANF, FLEX, LIN, IIS, or M1553.
Example
:TRIGger:MODE SLOPe
:TRIGger:MODE?

:TRIGger:COUPling

Syntax
:TRIGger:COUPling <couple>
:TRIGger:COUPling?
Description
Selects or queries the trigger coupling type.
Parameter
Name
<couple>
Remarks
This command is only available for the Edge trigger in which the analog channel is
selected as the source.
AC: blocks any DC components.
DC: allows DC and AC components to pass the trigger path.
LFReject: blocks the DC components and rejects the low frequency components.
HFReject: rejects the high frequency components.
Return
The query returns AC, DC, LFR, or HFR.
Format
Example
:TRIGger:COUPling LFReject
:TRIGger:COUPling?

:TRIGger:STATus?

Syntax
:TRIGger:STATus?
Description
Queries the current trigger status.
Return
The query returns TD, WAIT, RUN, AUTO, or STOP.
Format
MSO7000/DS7000 Programming Guide
Type
Range
{EDGE|PULSe|SLOPe|VIDeo|PATTern|DURation|
Discrete
TIMeout|RUNT|WINDow|DELay|SETup|NEDGe|
RS232|IIC|SPI|CAN|FLEXray|LIN|IIS|M1553
/*Selects the Slope trigger.*/
/*The query returns SLOP.*/
Type
Range
Discrete
{AC|DC|LFReject|HFReject}
/*Sets the trigger coupling type to low frequency
rejection.*/
/*The query returns LFR.*/
RIGOL
Default
EDGE
Default
DC
2-163