Chapter 2 Command System
:MEASure:CLEar
Syntax
:MEASure:CLEar <item>
Description
Clears any one or all of the 10 measurement items that have been turned on.
Parameter
Name
<item>
Remarks
Run the
be measured. The 10 measurement items turned on last time are determined by the
order in which you turned them on, and they will not be affected if you delete one or
multiple measurement items.
Example
:MEASure:CLEar ITEM1
:MEASure:THReshold:SOURce
Syntax
:MEASure:THReshold:SOURce <source>
Description
Sets the threshold source.
Parameter
Name
<source>
Remarks
Modifying the threshold will affect the measurement results of time, delay, and phase
parameters.
Example
:MEASure:THReshold:SOURce CHANnel2
:MEASure:THReshold:DEFault
Syntax
:MEASure:THReshold:DEFault
Description
Sets the threshold level of the analog channel in auto measurement to a default value.
:MEASure:MODE
Syntax
:MEASure:MODE <mode>
:MEASure:MODE?
Description
Sets or queries the measurement mode.
Parameter
Name
<mode>
Remarks
NORMal: executes measurement of up to 1 Mpts.
PRECision: executes measurement of up to 500 Mpts, improving the resolution of
measurement results. Note, in this mode, the refresh rate of the waveforms may be
reduced.
Example
The query returns NORM or PREC.
:MEASure:MODE PRECision
:MEASure:MODE?
MSO7000/DS7000 Programming Guide
Type
Range
{ITEM1|ITEM2|ITEM3|ITEM4|ITEM5|ITEM6|I
Discrete
TEM7|ITEM8|ITEM9|ITEM10|ALL}
:MEASure:ITEM
command to open one of the 41 parameters that is required to
/*Clears a measurement item ITEM1.*/
Type
Range
{CHANnel1|CHANnel2|CHANnel3|CHANnel4|
Discrete
MATH1|MATH2|MATH3|MATH4}
Type
Range
Discrete
{NORMal|PRECision}
/*Sets the threshold source to CH2.*/
/*Sets the measurement mode to PRECision.*/
/*The query returns PREC.*/
RIGOL
Default
——
Default
CHANnel1
Default
NORMal
2-109