Measure:counter:enable; Measure:counter:source; Measure:counter:value - Rigol DS7034 User Programming Manual

Mso7000 series; ds7000 series; digital oscilloscope
Hide thumbs Also See for DS7034:
Table of Contents

Advertisement

RIGOL
Remarks
Only the currently enabled channels can be selected.
Return
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14,
Format
D15, CHAN1, CHAN2, CHAN3, CHAN4, MATH1, MATH2, MATH3, or MATH4.
Example
:MEASure:SOURce CHANnel2 /*Sets the channel source for the parameter to CH2.*/
:MEASure:SOURce?

:MEASure:COUNter:ENABle

Syntax
:MEASure:COUNter:ENABle <bool>
:MEASure:COUNter:ENABle?
Description
Enables or disables the frequency counter; or queries the on/off status of the
frequency counter.
Parameter
Name
<bool>
Return
The query returns 1 or 0.
Format
Example
:MEASure:COUNter:ENABle ON
:MEASure:COUNter:ENABle?

:MEASure:COUNter:SOURce

Syntax
:MEASure:COUNter:SOURce <source>
:MEASure:COUNter:SOURce?
Description
Sets or queries the measurement source of the frequency counter.
Parameter
Name
<source>
Remarks
Only the currently enabled channels can be selected.
Return
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14,
Format
D15, CHAN1, CHAN2, CHAN3, CHAN4, or EXT.
Example
:MEASure:COUNter:SOURce CHANnel2 /*Sets the measurement source for the
:MEASure:COUNter:SOURce?

:MEASure:COUNter:VALue?

Syntax
:MEASure:COUNter:VALue?
Description
Queries the measurement results of the frequency counter. The default unit is Hz.
Return
The query returns the current measurement value in scientific notation. If the frequency
Format
counter function is currently disabled, the query returns 0.
Example
:MEASure:COUNter:VALue?
2-108
/*The query returns CHAN2.*/
Type
Range
{{1|ON}|{0|OFF}}
Bool
/*Enables the frequency counter.*/
/*The query returns 1.*/
Type
Range
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D
Discrete
11|D12|D13|D14|D15|CHANnel1|CHANnel2
|CHANnel3|CHANnel4|EXT}
/*The query returns 1000.*/
frequency counter to CH2.*/
/*The query returns CHAN2.*/