:BUS<n>:CAN:BAUD
Syntax
:BUS<n>:CAN:BAUD <baud>
:BUS<n>:CAN:BAUD?
Description
Sets or queries the signal rate of CAN decoding. The default unit is bps.
Parameter
Name
<n>
<baud>
Remarks
If the baud rate is set to a value with "M", then "A" should be added at the end of the
value. For example, if you send 5 M, you need to send 5 MA.
Return
The query returns an integer ranging from 10 kbps to 5 Mbps.
Format
Example
:BUS1:CAN:BAUD 120000
:BUS1:CAN:BAUD?
:BUS<n>:CAN:SPOint
Syntax
:BUS<n>:CAN:SPOint <spoint>
:BUS<n>:CAN:SPOint?
Description
Sets or queries the sample point position of CAN decoding (expressed in %).
Parameter
Name
<n>
<spoint>
Remarks
Sample point is a point within a bit's time. The oscilloscope samples the bit level at this
point. The sample point position is expressed as the ratio of "time from the bit start to
the sample point" to "bit time", in %.
Return
The query returns an integer ranging from 10 to 90.
Format
Example
:BUS1:CAN:SPOint 70
:BUS1:CAN:SPOint?
2-30
Type
Range
Discrete
{1|2|3|4}
Integer
10 kbps to 5 Mbps
/*Sets the signal rate of CAN decoding to 120000 bps.*/
/*The query returns 120000.*/
Type
Range
Discrete
{1|2|3|4}
Integer
10 to 90
/*Sets the sample point position of CAN decoding to 70%.*/
/*The query returns 70.*/
Chapter 2 Command System
Default
——
1 Mbps
Default
——
50
MSO7000/DS7000 Programming Guide