Trigger:flexray (Option) - Rigol DS7034 User Programming Manual

Mso7000 series; ds7000 series; digital oscilloscope
Hide thumbs Also See for DS7034:
Table of Contents

Advertisement

Chapter 2 Command System

:TRIGger:FLEXray (Option)

Command List:
:TRIGger:FLEXray:BAUD
:TRIGger:FLEXray:LEVel
:TRIGger:FLEXray:SOURce
:TRIGger:FLEXray:WHEN
:TRIGger:FLEXray:BAUD
Syntax
:TRIGger:FLEXray:BAUD <baud>
:TRIGger:FLEXray:BAUD?
Description
Sets or queries the signal rate of FlexRay trigger. The default unit is bps.
Parameter
Name
<baud>
Return
The query returns 2500000, 5000000, or 10000000.
Format
Example
:TRIGger:FLEXray:BAUD 5000000
:TRIGger:FLEXray:BAUD?
:TRIGger:FLEXray:LEVel
Syntax
:TRIGger:FLEXray:LEVel <level>
:TRIGger:FLEXray:LEVel?
Description
Sets or queries the trigger level of FlexRay trigger. Its unit is the same as that of the
current amplitude.
Parameter
Name
<level>
Remarks
For VerticalScale, refer to the
the
:CHANnel<n>:OFFSet
Return
The query returns the trigger level in scientific notation.
Format
Example
:TRIGger:FLEXray:LEVel 0.16
:TRIGger:FLEXray:LEVel?
MSO7000/DS7000 Programming Guide
Type
Range
Discrete
{2500000|5000000|10000000}
Type
Range
(-5 × VerticalScale - OFFSet) to
Real
(5 × VerticalScale - OFFSet)
:CHANnel<n>:SCALe
command.
/*Sets the trigger level to 160 mV.*/
/*The query returns 1.600000E-1.*/
/*Sets the signal rate to 5000000 bps.*/
/*The query returns 5000000.*/
command; for OFFSet, refer to
RIGOL
Default
10000000 bps
Default
0 V
2-213