RIGOL
channels "D0 to D15".
In the parameter range, H indicates high level (higher than the threshold level of
the channel), L indicates low level (lower than the threshold level of the channel),
and X indicates omitting the channel (This channel is not used as a part of the
pattern. When all the channels are set to X, the oscilloscope will not trigger.)
Return
The query returns the currently set pattern of all the channels. The channels are
Format
separated by commas.
Example
:TRIGger:DURATion:TYPE L,X,H,L
:TRIGger:DURATion:TYPE?
:TRIGger:DURATion:WHEN
Syntax
:TRIGger:DURATion:WHEN <when>
:TRIGger:DURATion:WHEN?
Description
Sets or queries the trigger condition of Duration trigger.
Parameter
Name
<when>
Remarks
GREater: triggers when the set duration time of the pattern is greater than the preset
time.
LESS: triggers when the set duration time of the pattern is smaller than the preset
time.
GLESs: triggers when the set duration time of the pattern is smaller than the preset
upper time limit and greater than the preset lower time limit.
UNGLess: triggers when the set duration time of the pattern is greater than the
preset upper time limit and smaller than the preset lower time limit.
Return
The query returns GRE, LESS, GLES, or UNGL.
Format
Example
:TRIGger:DURATion:WHEN LESS
:TRIGger:DURATion:WHEN?
:TRIGger:DURATion:TUPPer
Syntax
:TRIGger:DURATion:TUPPer <time>
:TRIGger:DURATion:TUPPer?
Description
Sets or queries the upper limit of the duration time of Duration trigger. The default unit is
s.
Parameter
Name
<time>
Remarks
This command is only available when the trigger conditions are LESS and GLESs.
Return
The query returns the upper limit of the duration time in scientific notation.
Format
Example
:TRIGger:DURATion:TUPPer 0.000003 /*Sets the upper limit of the duration time to 3
:TRIGger:DURATion:TUPPer?
2-178
Type
Range
Discrete
{GREater|LESS|GLESs|UNGLess}
Type
Range
Real
800 ps to 10 s
/*Sets the patterns of "CH1 to CH4" to L,X,H,L.
Other channel pattern remains unchanged.*/
/*The query returns
L,X,H,L,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X.*/
/*Sets the trigger condition to LESS.*/
/*The query returns LESS.*/
μs.*/
/*The query returns 3.000000E-6.*/
MSO7000/DS7000 Programming Guide
Chapter 2 Command System
Default
GREater
Default
2 μs