:MEASure:COUNter:VALue?

Syntax
:MEASure:COUNter:VALue?
Description
Query the measurement result of the frequency counter. The default unit is Hz.
Return
The query returns the measurement result in scientific notation. If the frequency counter
Format
is disabled, 0.0000000e+00 will be returned.
Example
:MEASure:COUNter:VALue?
Related
:MEASure:COUNter:SOURce
Command

:MEASure:CLEar

Syntax
:MEASure:CLEar <item>
Description
Clear one or all of the last five measurement items enabled.
Parameter
Name
<item>
Explanation
You can use the
37 waveform parameters. Note that the last five parameters are determined
according to the order in which you turned them on and they will not change as you
delete one or more measurement items.
You can send the
item or all the items are cleared.
Example
:MEASure:CLEar ITEM1

:MEASure:RECover

Syntax
:MEASure:RECover <item>
Description
Recover the measurement item which has been cleared.
Parameter
Name
<item>
Explanation
You can use the
37 waveform parameters. Note that the last five parameters are determined
according to the order in which you turned them on and they will not change as you
delete one or more measurement items.
You can send the
of the measurement items are recovered.
MSO1000Z/DS1000Z Programming Guide
/*The query returns 1.000004e+03*/
Type
Range
Discrete
{ITEM1|ITEM2|ITEM3|ITEM4|ITEM5|ALL}
:MEASure:ITEM
:MEASure:RECover
/*Clear ITEM1*/
Type
Range
{ITEM1|ITEM2|ITEM3|ITEM4|ITEM5|ALL}
Discrete
:MEASure:ITEM
:MEASure:CLEar
command to enable the desired parameters of the
command to recover the item(s) when a certain
command to enable the desired parameters of the
command to clear the items again after one or all
RIGOL
Default
--
Default
--