Power Characteristics

Table 22: Pilot power characteristics

Power
Value
characteristic
Frequency
50–60Hz
AC voltage
100–240V
Maximum
314 VA
power
consumption for
both nodes
Current draw
1.42A, 208V
for both nodes
Maximum heat
1102 BTU/hr
dissipation
AC receptacle
IEC 60320 C14 inlet
type

Table 23: Controller power characteristics

Power
Value
characteristic
Frequency
50–60 Hz (47–63 Hz range)
(nominal)
Voltage
100 to 127/200 to 240 Volts AC
(nominal)
Input current
13.6 A at 100–120 Volts AC (approximately)
(maximum) for
8 A at 200–240 Volts AC (approximately)
both nodes
Maximum
874 VA (power at maximum FS1 Controller configuration)
power
consumption for
both nodes
Maximum heat
2830 BTU/hr
dissipation
AC receptacle
IEC 60320 C14 inlet
type