Caution: Do not use the power supply handles to lift the chassis. Using the
power supply handles to lift the chassis can damage the power cooling
modules and disrupt electrical power to the Drive Enclosure.
2
Angle the Drive Enclosure slightly to the left and align the left side slider
on the Drive Enclosure so that it engages with the left rail channel.

Figure 44: Left rail channel

Legend
1 Left rail channel
3
Slightly tug the Drive Enclosure to the right and align the right side slider
on the Drive Enclosure so that it engages with the right rail channel.
4
Apply even pressure to both sides of the Drive Enclosure and carefully
slide the Drive Enclosure into the rails.
Note: The Drive Enclosure must be fully seated in the rack. To verify that
the Drive Enclosure is fully seated, check for the following:
Using a flashlight, visually check to see that the sliders on both sides
of the Drive Enclosure are in the rail channels on both sides of the
rack. If the Drive Enclosure side sliders are not in the rail channels,
then the Drive Enclosure is not seated. You must reinsert the Drive
Enclosure.
Ensure that the Drive Enclosure slides smoothly into the rack and
out of the rack. If the Drive Enclosure does not slide smoothly in and
out of the rack, then the Drive Enclosure is not seated. You must
reinsert the Drive Enclosure.
Ensure that the screw hole at the back of the Drive Enclosure aligns
with the screw hole on the rail. Do not secure the screw, yet. If the
screw hole at the back of the Drive Enclosure does not align with the