Slide Controller To Service Position - Oracle FS1-2 Customer Service Manual

Flash storage system
Hide thumbs Also See for FS1-2:
Table of Contents

Advertisement

You can select one of the following methods to identify the chassis:
Identify
Reverse Identify
7
Click Next.
Based on the method you selected to identify the chassis, the
corresponding LEDs flash to help you locate the chassis in the data center.
8
Click Next.
Guided Maintenance sends a request to shut down the software running
on the Controller and automatically initiates failover. Guided Maintenance
also displays an HTML link that you use to access the instructions for
component replacement.

Slide Controller to Service Position

Squeeze the release buttons on either side of the Controller front panel at
the same time and slide the Controller chassis forward until the slide rails
lock into position. You might have to remove screws locking the front
panel to the rack before the Controller slides forward.
Caution: Deploy any rack anti-tilt mechanism before releasing the release
buttons and extending the Controller chassis.
Flashes the LEDs on the chassis that contains the failed component.
Flashes the LEDs on all of the chassis in the system except for the chassis that
contains the failed component.
Controller Replacement Procedures
111