Standard Models and Specifications
2-8
Absolute Encoder Backup Battery Specifications
A backup battery is required when using a Servomotor with an absolute encoder.
Install the Battery Unit in the battery holder for the Absolute Encoder Battery Cable
(R88A-CRWC0R3C, 0.3 m), and connect the provided connector to the connector in
the battery holder.
R88A-BAT01W Absolute Encoder Backup Battery Unit
■
Specifications
■
Item
Battery model number
Battery voltage
Current capacity
Connection Configuration and External Dimensions
■
Wiring
■
Cable: AWG24 × 2C UL1007
2-122
ER3V (Toshiba)
3.6 V
1,000 mA·h
t = 6
5
26
L
6.8
No.
Symbol
Red
1
BAT
Black
2
BATGND
Connector housing: DF3-2S-2C (Hirose Electric)
Contact pin: DF3-2428SCFC (Hirose Electric)
Specifications
Model
R88A-BAT01W
Chapter 2
Length (L)
20 mm