Standard Models and Specifications
2-10 MECHATROLINK-II Repeater Specifications
The MECHATROLINK-II Repeater is required to extend the MECHATROLINK-II connection distance.
FNY-REP2000
■
Item
Cable lengths
Maximum number of
stations
Indicators
Power supply current
External power supply
Weight
Repeater Part Names
Power indicator (POWER)
CN1 transmitting indicator (TX1)
CN2 transmitting indicator (TX2)
2-126
Controller to Repeater: 50 m max.
Repeater to terminating resistance: 50 m max.
14 stations over 50 m or 15 stations over 30 m from Controller to Repeater
15 stations over 50 m or 16 stations over 30 m from Repeater to terminating resis-
tance
Also, the number of stations on both sizes of the Repeater must not exceed the
maximum number of stations for the Controller. (The maximum is 16 stations for the
CS1W/CJ1W-NCF71.)
Three: Power, CN1 transmitting, and CN2 transmitting
180 mA max.
100 mA at 24 VDC ( ± 4.8 V)
0.5 kg
Specification
DIP Switch
Leave all pins set to OFF.
MECHATROLINK-II
communications connectors (CN1 and CN2)
Control power supply terminals (24 VDC and 0 VDC)
Protective ground terminal
Chapter 2