Appendix
Param-
Parame-
eter No.
ter name
Digit
No.
Pn801
Function
0
selection
applica-
tion 6
(software
LS)
1
2
3
Pn802
Not used.
(Do not change setting.)
Pn803
Zero point
Sets the origin position detection range.
width
Pn804
Forward
Sets the software limit for the positive direction.
software
Note: Pn806 must be set lower than Pn804.
limit
Pn806
Reverse
Sets the software limit for the negative direction.
software
Note: Pn806 must be set lower than Pn804.
limit
Pn808
Absolute
Sets the encoder position and machine coordinate sys-
encoder
tem offsets for when an absolute encoder is used.
zero point
position
offset
Pn80A
First step
Sets the step 1 acceleration for when two-step accelera-
linear
tion is used.
accelera-
tion
parameter
Pn80B
Second
Sets the step 2 acceleration for when two-step accelera-
step lin-
tion is executed, or the one-step acceleration parameter
ear accel-
for when one-step acceleration is executed.
eration
parameter
Pn80C
Accelera-
Sets the switching speed for the step 1 and step 2 accel-
tion
eration when two-step acceleration is executed.
parame-
Note: When used as one-step acceleration, 0 must be
ter switch-
set.
ing speed
Pn80D
First step
Sets the step 1 deceleration for when two-step decelera-
linear
tion is used.
decelera-
tion
parameter
Pn80E
Second
Sets the step 2 deceleration for when two-step decelera-
step lin-
tion is executed, or the one-step deceleration parameter
ear decel-
for when one-step deceleration is executed.
eration
parameter
Pn80F
Decelera-
Sets the switching speed for the step 1 and step 2 decel-
tion
eration when two-step deceleration is executed.
parame-
Note: When used as one-step acceleration, 0 must be
ter switch-
set.
ing speed
Pn810
Exponen-
Sets the bias for when an exponential filter is used for the
tial accel-
position command filter.
eration/
decelera-
tion bias
Explanation
Name
Setting
Explanation
Software
0
Software limit enabled.
limit function
1
Forward software limit
disabled.
2
Reverse software limit
disabled.
3
Forward/reverse soft-
ware limits disabled.
Not used.
0
(Do not change setting.)
Software
0
No software limit check
limit check
using reference
using refer-
1
Software limit check
ence
using reference
Not used.
0
(Do not change setting.)
Default
Unit
Setting
setting
range
0003
---
---
0000
---
---
10
Command
0 to 250
unit
− 1073741823
8191
Command
91808
unit
to
1073741823
− 8191
− 1073741823
Command
91808
unit
to
1073741823
− 1073741823
0
Command
unit
to
1073741823
× 10000
100
1 to 65535
Command
2
unit/s
× 10000
100
1 to 65535
Command
2
unit/s
× 100
0
0 to 65535
Command
unit/s
× 10000
100
1 to 65535
Command
2
unit/s
× 10000
100
1 to 65535
Command
2
unit/s
× 100
0
0 to 65535
Command
unit/s
0
Command
0 to 32767
unit/s
Chapter 6
Restart
Set
power?
value
---
0@0@
---
---
---
---
---
---
---
---
---
---
---
---