Operation
Pn52A
Not used.
Setting
---
range
Note Do not change setting.
Pn52F
Not used.
Setting
---
range
Note Do not change setting.
Program JOG: Pn530 to Pn536
Pn530.0
Program JOG operation related switches -- Program JOG operating pattern (All operation
modes)
Setting
0 to 5
range
Setting Explanation
Setting
(Waiting time Pn535 → Forward movement Pn531) × Number of movement operations Pn536
0
(Waiting time Pn535 → Reverse movement Pn531) × Number of movement operations Pn536
1
(Waiting time Pn535 → Forward movement Pn531) × Number of movement operations Pn536
2
(Waiting time Pn535 → Reverse movement Pn531) × Number of movement operations Pn536
(Waiting time Pn535 → Reverse movement Pn531) × Number of movement operations Pn536
3
(Waiting time Pn535 → Forward movement Pn531) × Number of movement operations Pn536
(Waiting time Pn535 → Forward movement Pn531 → Waiting time Pn535 → Reverse movement
4
Pn531) × Number of movement operations Pn536
(Waiting time Pn535 → Reverse movement Pn531 → Waiting time Pn535 → Forward movement
5
Pn531) × Number of movement operations Pn536
Pn530.1
Program JOG operation related switches -- Not used.
Setting
---
range
Note Do not change setting.
Pn530.2
Program JOG operation related switches -- Not used.
Setting
---
range
Note Do not change setting.
Pn530.3
Program JOG operation related switches -- Not used.
Setting
---
range
Unit
---
Unit
---
Unit
---
Unit
---
Unit
---
Unit
---
Default
20
setting
Default
FFF
setting
Default
0
setting
Explanation
Default
0
setting
Default
0
setting
Default
0
setting
Chapter 4
Restart
No
power?
Restart
No
power?
Restart
No
power?
Restart
No
power?
Restart
No
power?
Restart
No
power?
4-65