13.Waveform Comparison / Waveform and Displacement Comparison Mode
Example2 : In cace of OK
Waveform Start Level
START
STOP
Judgment
Output
(OK1)
Judgment
Output
(HI1, LO1)
COMPLETE
t1: Delay time between the instant when the indicated value exceeds the waveform start
t2: Delay time between the instant when the START signal is input and the instant when
t3: Minimum START signal width Ts+0.8msec (min.)
t4: Standby time to start the next comparison Approx. 300msec
t5: Delay time between the instant when the STOP signal is input and the instant when
t6: Delay time between the instant when the START signal is input and the instant when
t7: Delay time between the instant when the comparison ends and the instant when
77
Input waveform
t1
t2
OFF
ON
t3
OFF
ON
OFF
ON
t6
OFF
ON
OFF
ON
level and the instant when the hold is detected. Ts msec (max.)
the comparison starts. Ts+0.8msec (max.)
the area ends Ts+0.8msec (max.)
the judgment output and COMPLETE change. Ts+1.6msec (max.)
COMPLETE turns ON. 0.8ms (max.)
The COMPLETE output turns OFF when the power is turned on and
reset operation, such as switching the operation ch, is performed.
Comparison waveforms
Comparison period
End of the comparison
area, inputting of the
STOP signal, excess of
2048 points, or crossing
over the waveform
termination level (when
the signal "Waveform
terminal level operation"
is ON)
t
Next
t4
comparison
t5
t7