Displacement High-Low Mode / Displacement High Limit; Displacement Low Limit / Displacement Hold High Limit; Displacement Hold Low Limit - Unipulse f395 Operation Manual

Dynamic force processor
Table of Contents

Advertisement

Indicated value
LO-LO Limit
HI-HI Limit /
LO-LO Limit
・ The OK signal is output when the Set Value of Low Limit ≦ Indicated
Value ≦ the Set Value of High Limit, and the Set Value of LO-LO Limit
≦ Comparison Value ≦ the Set Value of HI-HI Limit.
・ The HI-HI Limit / LO-LO Limit setting is used for difference judgment in
the Hysteresis 2 mode. (See "12-1. Function" P65.) Also, it is used for
High/Low Limit Judgment of hold points in the Waveform Comparison /
Waveform and Displacement Comparison mode. (See "13-7. Hold
Operation" P78.)
・ The results of HI-HI Limit / LO-LO Limit Judgment are displayed
separately on the screen.
・ HI-HI Limit / LO-LO Limit Judgments can be made in the Relative mode
only when the HI-HI/LO-LO Mode is set at "Hold".
・ At Pulse-Hold time, the HI-HI/LO-LO Mode setting is effective only on
the operation ch at which sampling starts.

16-2-8. Displacement High-low Mode / Displacement High Limit /

Displacement Low Limit / Displacement Hold High Limit /

Displacement Hold Low Limit

In the Hysteresis / Hysteresis 2 / Waveform and Displacement Comparison mode, High/
Low Limit Judgments of the displacement value can be made by any one of the
following three types by the Displacement High-Low Mode setting.
Displacement High-low Mode
Setting item: Hold Value / Peak Value / Both
MODE
HI-HI Limit
High Limit
Low Limit
High Limit
GO
Low Limit
Code Set
OFF
Output Logic
ON
Judgment output signal
when the operation ch is switched
Judgment: DPM HI-LO Mode
16.Code Setting
110