24. Setting Items list
Mode
CH1 CAL.
EXC. Volt
Zero CAL
Equiv. CAL. (input value)
Equiv. CAL (load)
Actual CAL.
Digital Flt.
Analog Flt.
Decimal Place
Unit
Digital Offset
Increment
CH2 CAL.
Axis
EXC. Volt
Zero CAL.
Equiv.CAL. (input value)
Equiv.CAL. (magnitude)
Actual CAL.
Digital Flt.
Analog Flt.
Decimal Place
Unit
Digital Offset
Increment
Operation Mode
Operation Mode
Sample Rate
Code Set
Ch. No.
[0-31] ch
Parameter Copy
Select CH
Hold Set
HI Limit
HI-HI Limit
LO Limit
LO-LO Limit
DPM Hi
DPM LO
Wave Start Level
Wave End Level
Hold Timer
P&V Difference
P&V Judg. Rate
P&V Ordinal
Minimum Slope
Interval A
Interval B
Pre-Point
Inhibit Timer
Hys. Interval
F-T Limit
F-T Output
HH/LL Mode
Lv. Axis Select
Hold Start Level
Auto Code Up
Code Up Point
HI-LO Relative
DPM HI-LO Mode
DPM Hold HI
DPM Hold LO
U. Area Output
161
Setting item
Initial value
2.5V
2.000
500.0
500.0
None
600Hz
xxx.x
kN
0.0
0.1
2.5V
5.000
500.0
500.0
None
600Hz
xxx.x
kN
0.0
kN
Multi-hold
1kHz
CH1
None
+100.0
+999.9
+1.0
-999.9
999.9
0.0
+1.0
+0.0
1000
1.0
25%
1.0
20
20
1.0
4000
ON
Hold
Y Axis
-9999(Invalidity)
OFF
OFF
Peak value
9999
ON
NOV.
SRAM LOCK
LOCK
RAM
(SW)
(SOFT)
0: 2.5V 1: 10V
◎
◎
○
Execution screen
◎
◎
○
4 digits (The explanatory display is changed
◎
◎
○
according to the mounting condition.)
4 digits
◎
◎
○
4 digits (The explanatory display is changed
◎
◎
○
according to the mounting condition.)
0: None 1: 2 2: 4 3: 8 4: 16 5: 32
◎
◎
0: 10Hz 1: 50Hz 2: 200Hz 3: 600Hz
◎
◎
0: x, 1: x.x 2: x.xx 3: x.xxx
◎
◎
○
◎
◎
○
0:kg
5:MN
10:bar
15:rad
20:psig
25:in
4 digits + sign
◎
◎
◎
3 digits
◎
◎
◎
Status display
0: 2.5V 1: 10V (The setting cannot be made
◎
◎
○
depending on the mounting condition.)
Execution screen
◎
◎
○
4 digits (The explanatory display is changed
◎
◎
○
according to the mounting condition.)
4 digits (The explanatory display is changed
◎
◎
○
according to the mounting condition.)
4 digits (The explanatory display is changed
◎
◎
○
according to the mounting condition.)
0: None 1: 2 2: 4 3: 8 4: 16 5: 32
◎
◎
0: 10Hz 1: 50Hz 2 :200Hz 3: 600Hz
◎
◎
0: x, 1: x.x 2: x.xx 3: x.xxx
◎
◎
○
◎
◎
○
0:kg
5:MN
10:bar
15:rad
20:psig
25:in
4 digits + sign (only plus at X-axis setting)
◎
◎
◎
3 digits
◎
◎
◎
0: Multi-hold 1: Wave Comp 2: Hysteresis
◎
◎
3: Wave & Displace 4: Hysteresis 2
0: 4k 1: 2k 2: 1k 3: 500 4: 200 5: 100
◎
◎
0
2 digits. 0 will result when the power is turned on.
◎
0
2 digits
◎
◎
0: CH1 1: CH2
◎
◎
See 16-2-4.
◎
◎
4 digits + sign
◎
◎
4 digits + sign
◎
◎
4 digits + sign
◎
◎
4 digits + sign
◎
◎
4 digits
◎
◎
4 digits
◎
◎
4 digits + sign
◎
◎
4 digits + sign
◎
◎
4 digits
◎
◎
4 digits
◎
◎
0: 25% 1: 50% 2: 75% 3: 125% 4: 150% 5: 200%
◎
◎
6 :300% 7: 400%
1
1 digits
◎
◎
4 digits
◎
◎
3 digits
◎
◎
3 digits
◎
◎
0
2 digits
◎
◎
0
4 digits
◎
◎
4 digits
◎
◎
4 digits
◎
◎
0: ON 1: OFF
◎
◎
0: Hold 1: Sample
◎
◎
0: Y Axis 1: X Axis
◎
◎
4 digits + sign
◎
◎
0: ON 1: OFF
◎
◎
0
4 digits
◎
◎
0: ON 1: OFF
◎
◎
0: Hold Value 1: Peak Value 2: Both
◎
◎
4 digits
◎
◎
0
4 digits
◎
◎
0: ON 1: OFF
◎
◎
Input digits or selections
1:t
2:g
3:N
4:kN
6:N•m
7:Pa
8:kPa
9:MPa
2
11:N/m
12:mm
13:cm
14:μm
16:deg
17:lb
18:oz
19:dyne
21:ftlb
22:inlb
23:inoz
24:ft
26:None
1:t
2:g
3:N
4:kN
6:N•m
7:Pa
8:kPa
9:MPa
2
11:N/m
12:mm
13:cm
14:μm
16:deg
17:lb
18:oz
19:dyne
21:ftlb
22:inlb
23:inoz
24:ft
26:None