Unipulse f395 Operation Manual page 41

Dynamic force processor
Table of Contents

Advertisement

4.Methods of Connection
・CODE1 ~ 16:
・STROBE:
・ Select output:
Judgment output signals
The results of High/Low Limit Judgment in each Operation Mode are output.
・LO1, OK1, HI1
27
Specifies operation ch for Hold mode, High/Low Limit, Comparison Waveform, etc.
(See "10-2. Setting and Operating Method" P47, "11-2. Setting and Operating
Method" P64, "12-2. Setting and Operating Method" P65, and "13-2. Setting and
Operating Method" P68.)
Changing of operation ch by changing CODE 1 ~ 16 is prohibited when this signal is
ON. (Previous operation ch is maintained.) Use to prevent chattering when changing
operation ch.
Output pin 44 ~ 46 (LO/OK/HI displacement 2) operate when this signal is ON.
- Pin 44/45 "Status" output
Status
WAITS / STOP
WAIT2
WAITL
SAMP / COPY
(For logic, see "4-3-4. Equivalent Circuit (Output)" P30. )
- Pin 46 "Level Edge" output (Present when this signal is ON. Use for level
edge clear, etc.)
When this signal is OFF, output pin 44 ~ 46 result in the operation of LO/OK/HI
displacement 2.
A level edge is generated when the input signal (indicated value)
crosses over the Waveform Start Level after the START signal is input.
It is cleared by starting sampling or inputting the STOP signal. (See "9.
Method of Starting Measurement" P43.)
: 1) When the Multi-Hold / Hysteresis mode is used.
Outputs the results of judgment of the load with respect to the
high limit / low limit.
2)When the Waveform Comparison / Waveform and Displace-
ment Comparison mode is used.
Outputs the results of judgment of the load with respect to the
high and low limit waveforms.
3) When the Hysteresis 2 mode is used.
Outputs the results of judgment of the load with respect to the
high limit / low limit, and the results of judgment of the
difference between go and return with respect to the hi-hi
limit / lo-lo limit.
Pin 44
Pin 45
0
0
1
0
0
1
1
1

Hide quick links: