18-4-9. Reading Indicated Values / Status

Y-axis reading
Host
R A
F395
X-axis reading
Host
R B
F395
Status reading
Host
R C
F395
Alarm
0: Normal
1: ADC+OVER
2: ADC-OVER
3: +OVER+
4: -OVER-
High Limit exceeded
0: High Limit or less
1: High Limit exceeded
2: HI-HI Limit exceeded
The status priority is as follows:
Alarm:
High Limit exceeded:
Low Limit exceeded:
Resolution of X-axis reading (The size to one data of the X-axis is read.)
Host
R D
F395
About the Reading Value
・In the Multi-Hold / Waveform
Comparison mode (X-axis is time.
)
Sampling rate
100Hz
200Hz
500Hz
1kHz
2kHz
4kHz
・ The X-axis reading (RB ~ ) can be used only in the Waveform and
Displacement Comparison / Hysteresis / Hysteresis 2 mode. In other
modes, indeterminate values are read.
・ The flag "Latest sampled waveform update" of the RC command is
cleared when the RC command is read.
Terminator
R A ±
Terminator
R B ±
Terminator
R C
S P
(ADC+OVER) > (ADC-OVER) > (+OVER+) > (-OVER-) > Normal
(HI-HI Limit exceeded) > (High Limit exceeded ) > (High Limit or less)
(LO-LO Limit exceeded) > (Low Limit exceeded) > (Low Limit or more)
Terminator
R D
S P
Reading value
0010. (ms)
0005. (ms)
0002. (ms)
0001. (ms)
000.5 (ms)
00.25 (ms)
0 0 . 0
Terminator
0 0 . 0
Terminator
0 0 0 0
Terminator
Not used
Reserved Latest sampled
waveform update
0: OFF
1: ON
Low Limit exceeded
0: Low Limit or less
1: Low Limit exceeded
2: LO-LO Limit exceeded
. 0 0 0
Terminator
・In the Hysteresis / Waveform and
Displacement Comparison / Hysteresis 2
mode (X-axis is displacement.)
The displayed value
on the item of actual
load calibration
0 ~ 2047
2048 ~ 4095
4096 ~ 8191
8192 ~ 9999
18.Interface
Reading value
(The decimal point
is arbitrary)
1
2
4
8
146