4.Methods of Connection
4-1-1-3. Voltage / Current Type Sensor Connection
Contact type, overcurrent type, laser type, and other voltage / current type sensors of up
to ± 5V / ± 20mA can be connected. (The analog input option is a factory-shipped
setting.)
4-1-1-4. Voltage Output (V-OUT) Connection
The relationship between sensor type and output voltage is as follows:
4-1-2. SI/F Connection
This is a 2-wire serial interface to connect a UNIPULSE-manufactured printer, external
display, etc.
Up to three nonpolarized external devices can be connected. Use parallel two-core
cables, cabtyre cables, and the like for wiring.
<Example of connection>
23
Voltage / current +
type sensor
Output
Within ± 5V/ ± 20mA
External equipment
Load resistance
5kΩ or more
Strain gauge
1mV/V ............ Approx. 2.0V
Voltage
5V ............. Approx. 5.6V
Current
20mA ............. Approx. 5.2V
No displacement sensor (for X-axis measurement) can be
connected when the PUI option is mounted.
Converter
Display
+ SIG
-
- SIG
+
V-OUT
GND
-
Printer
F395
F395
SI/F
F395