16-2-15. Forced-termination Limit

Set the number of samplings between the instant when displacement stops and the instant
when sampling is terminated forcedly.
Setting range: 0 ~ 9999 (If "0" is set, forced-termination is not performed.)
MODE → Code Set → Basic:

16-2-16. Forced-termination Output

Set whether or not to execute the HI/LO output at forced-termination time by a
displacement stop.
Setting item: ON / OFF
In the Waveform and Displacement Comparison / Hysteresis 2 mode
MODE → Code Set → Basic: F-T Output
In the Hysteresis mode
MODE → Code Set → Basic: PAGE → F-T Output

16-2-17. Un-passing Area Output

Set whether or not to output the OK signal when sampling does not pass the comparison
area in the Waveform Comparison / Waveform and Displacement Comparison mode.
(See "13-8. Un-passing Area Output" P80.)
Setting item: ON / OFF
MODE
Code Set → Judgment: U. Area Output
F-T Limit
16.Code Setting
120