12.Hysteresis 2
67
・ HI-HI Limit / LO-LO Limit Comparisons are not made.
・ If the operation ch is changed during measurement, the measurement is
stopped forcedly. (The results of previous judgments are not displayed.)
・ Each measurement will not be carried out until sampling starts.
・ Measurements are carried out with the Select Analog CH setting for the
operation ch at which sampling starts. The Select Analog CH setting for
operation ch+1/operation ch+2 is ineffective.
・ Do not input any pulse within the hysteresis interval because the result is
not judged normally.
・ No judgment is made if no pulse is input during go.
・ A difference judgment is made when the pulse-input displacement value
is reached during return measurement. (If two or more pulses are input at
the same displacement point during go measurement, judgments are
made by giving priority as pulse 1>pulse 2>pulse 3.)
・ Use of the Auto Code Up mode allows pulse input by the X-axis
measured value set under Code Up Point. (See "16-1. Method of Setting
the Operation ch" P100.)