・ The CODE for switching is necessary to perform Auto Code Up in return sampling.
Input larger value not to pass through in go sampling at Auto Code Up Point of code
for switching.
Example:
When CODE 0,1 are set for go sampling and CODE 3,4 are set for return sampling, use
CODE 2 for switching in line with the example of setting below.
Example:
CODE No.
Auto Code Up
Code Up Point
・ When the Hysteresis 2 mode is set, if the Auto Code Up is set to
"ON", pulse input by external signals is ineffective, but instead, in go
sampling, hold is executed when:
X-axis value ≧ Code up point
and in return sampling, when:
X-axis value ≦ Code up point.
・Only in the Auto Code Up mode, the High / Low Limit setting can be
used in the Relative mode. (See "16-2-6. High-Low Relative" P108.)
0
1
ON
ON
10.0mm
20.0mm
16.Code Setting
2
3
ON
ON
999.9mm
40.0mm
4
OFF
20.0mm
102