16-2-6. High-Low Relative

Only when sampling is performed in the auto code up mode, High/Low Limit Judgments
can be made in the Relative mode by setting the High-Low Relative to "ON".
Setting item: ON / OFF
MODE
In the Relative mode, High/Low Limit Judgments are made as follows:
Example of use of High-Low Relative:
When the High Limit Setting=100, and the Low Limit Setting=50
250
200
175
150
125
100
Code Set →
Y
Operation ch 0
Operation ch 1
100
75
50
100
50
Code up point
on operation ch 0
When the operation ch=0, since the reference value=0 at start-time,
high/low limit judgments are made with:
High Limit=100
Low Limit=50
When the operation ch=1, since the hold=75 on ch=0,
high/low limit judgments are made with:
High Limit=100 + 75 = 175
Low Limit= 50 + 75 = 125
When the operation ch=2 , since the hold=150 on ch=1,
high/low limit judgments are made with:
High Limit=100 + 150 = 250
Low Limit=50 + 150 = 200
When the operation ch=3 , since the hold=75 on ch=2,
high/low limit judgments are made with:
High Limit=100 + 75 = 175
Low Limit=50 + 75 = 125
Judgment: HI-LO Relative
Operation ch 2
Operation ch 3
100
50
50
Code up point
on operation ch 2
Code up point
on operation ch 1
16.Code Setting
100
50
X