Sign In
Upload
Manuals
Brands
Unipulse Manuals
Measuring Instruments
F377A
Unipulse F377A Manuals
Manuals and User Guides for Unipulse F377A. We have
2
Unipulse F377A manuals available for free PDF download: Operation Manual
Unipulse F377A Operation Manual (152 pages)
Digital Indicator
Brand:
Unipulse
| Category:
Measuring Instruments
| Size: 6.23 MB
Table of Contents
Table of Contents
6
Outline
14
Contents of the Package
14
About Connectable Devices
14
Appearance Description
15
Front Panel
15
Rear Panel
16
Installation & Connection
19
Installation
19
Connection
19
Power Input Connection
19
Analog Input / Output Terminals Connection
20
Voltage・Current Connection
21
F Connection
22
External I/O Connection
22
RS-232C Interface Connection
24
Voltage Output Connection
24
Connecting to Cage Clamp Terminal Block
25
Setting Procedure
26
Screens and Operations
26
Setting Modes Tree
26
F377A Screen Configuration
28
About a Setting Call
29
Calibration
30
Calibration Procedures
31
Calibration Protect
32
Calibration Value Selection
32
(This Step May be Omitted if There Is no Change.)31
32
Calibration Value Selection by Touch Panel
32
Calibration Value Selection by External Signal Input
33
Analog Input Selection
33
Unit
33
Zero Calibration
34
Equivalent Input Calibration
35
Registration Method at Decimal Place
35
Actual Load Calibration
36
Increment (this Step May be Omitted if There Is no Change.)
36
4-10.Digital Offset(this Step May be Omitted if There Is no Change.)
37
4-11.Digital Zero Limit(this Step May be Omitted if There Is no Change.)
37
Setting of Functions
38
Digital Zero
38
Digital Filter
39
Analog Filter
39
Motion Detect (MD)
39
Zero Tracking (ZT)
40
Backlight
40
Display Language Selection
41
F Print out
41
Indicate Color
42
5-10.Comparison Functions
42
HI Limit / lo Limit / HH Limit / LL Limit
43
Hysteresis
43
Near Zero
44
Comparison Timing
44
Comparison Output Selection
45
Alarm HI and lo Limits
46
5-11.Hold Functions
46
Hold Setting
46
Hold Setting
48
Hold Setting
49
Hold Setting
51
Hold Operation
51
How to Specify the Hold Detection Section(Peak, Valley, P-P, Average)
55
5-12.Multi-Hold Function
57
About Changing of the Setting Work
58
Work Copy
58
5-13.Measurement Work Selection
59
5-14.Control Input Selection
59
5-15.B6 off Detection Wait
59
5-16.B8 off Detection Wait
60
5-17.Waveform Display
60
Graphic Display Screen
60
Cursor Display Screen
60
Graph Plotting
61
Graph Mode
63
Interval Time
63
Graph Start Level
63
Level Detection Conditions
63
Time) End Point
64
Y(Load) Start Point and y(Load) End Point
64
5-18.Voltage Output
65
5-19.Screen Lock / Key Lock (B5 Terminal Function Selection)
65
5-20.Event Output at the End of Graph Plotting
66
5-21.RUN Output
66
5-22.RS-232C Interface
67
Communication Specifications
67
RS-232C Interface Setting
68
Communication Mode
68
Communication Format
69
BCD Data Output (Option)
73
Connector Pin Assignment
73
BCD Output Select
74
BCD Output Rate
74
Logic Switching
74
BCD Data Hold
74
Equivalent Circuit
75
Signal Timing
75
Self Check
76
D/A Converter (Option)
76
Scale Setting Value Selection
77
Zero Scale Output Value and Full Scale Output Value
77
D/A Output Select
78
External I/O (Source Type (ISC) Option)
79
Specifications
80
Analog Section
80
Digital Section
80
Standard Interfaces
81
Options Interfaces
81
External Input and Output
81
General
81
Accessories
82
Dimensions
82
Standard
82
Equipped with BCD Parallel Data Output Interface Option
83
Equipped with CC-Link Interface Option
83
Equipped with Device Net Interface Option
84
F377A Block Diagram
85
Supplements
86
Error Display List
86
Sensor +Error or Sensor -Error
86
Over or -Over (Overflow Error)
86
Overload (Overload Error)
86
Zero Error (Zero Calibration Error)
86
Span Error (Span Calibration Error)
86
Zero Limit (Digital Zero Limit Error)
86
Protect / Initialization
87
Work Setting Protect
87
System Setting Protect
87
Calibration Protect
87
Expansion Protect
87
Initialization
87
Self-Check
88
Password
89
Unit Setting List
89
Setting Item List
90
Work Setting Comparison Setting (WORK0 to WORK15)
90
Work Setting Hold Setting (WORK0 to WORK15)
90
Work Setting Graph Setting (WORK0 to WORK15)
91
Calibration (CAL0 to CAL3)
92
System Setting
92
Protect / Initialization
93
Self Check
93
Expansion
94
Exp. Hold Functions
98
Double Hold
98
Screens Appearing When Double Hold Is Selected
98
Double Hold Setting
99
Hold Operations
99
HI/LO Limit Comparisons of Double Hold
110
Sample Hold Trigger Edge Selection
111
Sample Trigger Selection Setting
112
Sample Trigger Select
112
Auto Reset Selection at the Start of Hold Detection
113
Auto Reset Select Setting
113
Hold Auto Reset
114
Hold off on Digital Zero
114
Renewal of Hold Value
115
Hold End Timing
116
Hold Operations
116
Exp. Comparison Functions
117
Before Value Comparison
117
Screens Appearing When before Value Comparison Is Selected
118
Before Value Renewal Condition
118
Difference HI/LO Limit Comparisons
118
Before Value Regulation
119
Before Value Comparison in Double Hold
119
Comparison Standard
119
Double Hold and Difference-HI/LO Limit Comparisons
120
Relative Value Comparison (in Expansion Double Hold Only)
121
Screens Appearing When Relative Value Comparison Is Selected
122
Relative-HI/LO Limit Comparison
123
Comparison Standard
123
Relative Value HI/LO Limit Comparison
123
Before Value Comparison and Relative Value Comparison
125
(In Expansion Double Hold Only)
125
Screens Appearing When before Value Comparison
125
Relative Value Comparison Are Selected
125
Difference Value- and Relative-HI/LO Limit Comparisons
125
Exp. Graph Function
127
Graph Pre Trigger Display Function
127
Pre Trigger Display Setting
127
Pre Trigger Value
127
Exp. Operation Functions
128
CR Characteristic (Primary) Digital Filter
128
Digital Filter Character
128
Averaging on Digital Zero
128
Average Time on Digital Zero
129
RUN Output Selection
129
Exp. Option Function
130
BCD Output Data Selection
130
Standard Interfaces
131
Rs-232C
131
Option Interfaces
138
BCO Option
138
BCD Output Data List
138
DAV/DAI Option
139
CC-Link Option
139
Devicenet Option
139
Supplements
140
Setting Item List
140
Work Setting Comparison Setting (WORK0 to WORK15)
140
Work Setting Hold Setting (WORK0 to WORK15)
142
Work Setting Graph Setting (WORK0 to WORK15)
146
RS-232C Special Setting Work Setting
146
RS-232C Special Setting Calibration Setting
146
Calibration (CAL0 to CAL3)
147
System Setting
148
Expansion Setting
150
Advertisement
Unipulse F377A Operation Manual (30 pages)
CC-Link I/F
Brand:
Unipulse
| Category:
Measuring Instruments
| Size: 0.48 MB
Table of Contents
Table of Contents
3
Appearance Descriptions
4
F372A/F377A with CC-Link I/F
4
Name of each Part
4
CC-Link I/F
4
F372A/F377A Setting
4
Communication Connector
5
Status LED
6
PLC Address
6
Address Map
7
Data Domain: Remote Resister M→R (PLC→F372A/F377A)
7
Explanation for Remote Resister M → R
8
Data Domain: Remote Resister R→M (F372A/F377A→PLC)
9
Explanation for Remote Resister R → M
10
Relay Domain
12
RY (PLC→F372A/F377A) Signal
18
RX (F372A/F377A→PLC) Signal
19
Setting Procedure
20
Set Value Writing in the Exclusive Data Area (Using Request Flag 1)
20
(Using Request Flag 2)
20
Set Value Reading in the General-Purpose Data Area (Using Request Flag 2)
21
Sample of Ladder Program
22
Alarm Codes
25
Unit Setting List
26
Command List
27
Advertisement
Related Products
Unipulse F370
Unipulse F325
Unipulse F320
Unipulse F701+
Unipulse F372A
Unipulse F371
Unipulse DeviceNet F381A
Unipulse F340A
Unipulse f395
Unipulse DeviceNet F388A
Unipulse Categories
Measuring Instruments
Touch Panel
Controller
Accessories
Monitor
More Unipulse Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL